1 Pair 8-Blade Diameter 40mm Ducted Fan Std Reverse (Integral Type) Use For RC Plane No Include D/F No Include Shaf
Packing include: 1 std+1 Reverse
Aperture: 3mm
Thickness of Center: 17mm

This integrated 8-blade ducted fan converts motor rotation into thrust for electric ducted fan RC aircraft. One standard rotation ducted fan and one reverse rotation ducted fan are supplied as a pair, suitable for counter-rotating EDF setups. This ducted fan is a direct replacement or spare part for 40mm EDF projects. It comes as an all-in-one moulded unit, with blades and hub formed as a single piece. It does not include ducted fan shroud or drive shaft. Modellers commonly keep spare EDF ducted fans for crash replacement, as fan blades are vulnerable to damage from debris or ground impact during operation.
This ducted fan is injection-moulded plastic, the standard material for small-size EDF units. Integrated one-piece construction eliminates loose blades, simplifying assembly. The central hub has a 3mm mounting aperture to fit compatible motor shafts. The moulded blade profile is engineered for ducted fan airflow characteristics. Factory balance is not guaranteed; static and dynamic balancing before operation is standard industry practice for all EDF ducted fans. Plastic will crack or deform on heavy impact to reduce shock transfer to the connected motor.
Diameter: 40mm Aperture: 3mm Center thickness:17mm This ducted fan is built specifically for 40mm electric ducted fan units. Confirm the internal space of your EDF shroud before purchase. Match the 3mm hub aperture to your motor shaft or adapter. Shaft and ducted fan shroud are sold separately and not contained in this pack. Manual measurement tolerance applies to all listed dimensions. Product photos are for reference only.
This set contains one standard and one reverse 8-blade ducted fan. Reverse ducted fans are used in counter‑rotating dual EDF configurations to cancel torque effect. 8-blade design generates steady airflow inside the duct, delivering compact thrust for small EDF RC airframes. This ducted fan is for electric ducted fan power systems only, not compatible with glow or gasoline engines.
Small EDF jet RC planes: Fits 40mm diameter electric ducted fan setups for micro jet models. Counter-rotating EDF builds: Standard + reverse pair works for twin counter‑rotating duct power systems. Spare replacement: Ideal to replace damaged ducted fans after impact or debris ingestion. Custom EDF assembly: For builders assembling custom 40mm ducted fan power units.
| No. | Description | Value |
|---|---|---|
| 1 | Blade Quantity | 8 blades, integrated type |
| 2 | Diameter | 40mm |
| 3 | Aperture | 3mm |
| 4 | Center Thickness | 17mm |
Measurement deviation: 1–3mm for manually measured values.
Package Includes: 1pc standard ducted fan + 1pc reverse ducted fan
Select a motor shaft or adapter matching the 3mm hub aperture. Secure the ducted fan firmly and ensure it runs co‑axially with the motor shaft. Complete static balance then dynamic balance testing before powering up. Unbalanced EDF ducted fans produce strong vibration that can damage motor bearings and loosen airframe fittings. Inspect every blade and hub carefully before each run. Even tiny nicks or cracks from debris ingestion can lead to fan failure at high RPM. Confirm the ducted fan spins freely inside the duct without rubbing the shroud inner wall.
Inspect the ducted fan after every flight. If the blades touch foreign objects, check for hidden cracks or deformation. Damaged ducted fans must be replaced immediately. Store spare ducted fans away from heat and heavy pressure to prevent warping of the thin blades. If you install this ducted fan on a new motor, monitor motor temperature during testing. Mismatched KV or voltage can overload the power system. Keep spare ducted fans on hand for quick field replacement.
For the great amount of propellers with varied types of different purposes, users should fly with them follow the instruction below for safety:
1.Please run your propeller with proper power system, and please do some necessary adjustment with test of static/ dynamic balance seriously, or you will easily have it damaged;
2.When the power system is working, please make sure that there is no one standing in front or on either side of it ( or its intake, if it is an electric ducted fan power system), preventing it from flying off unexpectedly and causing danger;
3.If there are some cracks or any structural damages on the propeller, please displace another one as soon as possible to prevent it from flying off into pieces and causing danger;
4.Before flying, please make sure the propeller is fixed well through the motor shaft and the two of which are in the same axis;
5. Please make sure the runway is clean, because such things like branches and little stones and easily cause danger and damage to people all around and the plane itself.
Q: What comes with this order?
A: The pack includes 1 standard 8-blade ducted fan and 1 reverse 8-blade ducted fan. Ducted fan shroud and shaft are not included.
Q: What shaft size does this ducted fan fit?
A: The hub aperture is 3mm, match it with your motor shaft or 3mm adapter.
Q: Can I run this without balancing?
A: No. Static and dynamic balancing is required before use. Unbalanced EDF ducted fans create dangerous vibration at high RPM.
Q: What is the difference between standard and reverse ducted fan?
A: They spin in opposite directions, mainly used for counter‑rotating twin EDF setups to offset torque.
Q: Can this ducted fan work for gas or glow engines?
A: No. It is designed exclusively for electric ducted fan power systems.